Material Number – Laboratory and table-top autoclaves from 25 to 200 litres chamber volume
Autoclaves
Laboratory and table-top autoclaves from 25 to 200 litres chamber volume
Our benchtop autoclaves not only fit on every laboratory bench, the chamber is also designed to achieve an optimal loading capacity with many standard bottles (e.g. Schott) and Erlenmeyer flasks. Our laboratory and benchtop autoclaves are available in six different sizes. A special feature is the angular chamber of the autoclaves Labstar 40 and LabStar 70. They offer a much higher loading capacity than a round-chamber instrument with almost identical external dimensions.
Type | Volume (Litres) | chamber dimension (WxHxD) mm | external dimensions (WxHxD) mm | Heating capacity kW | electrical supply |
Labstar 25 | 24 R | Ø 300 x 360 | 450 x 525 x 640 | 2,5 | 240V 50Hz 16A 115V 60Hz 20A |
Labstar 40 | 42 S | 295 x 295 x 460 | 532 x 605 x 697 | 2,5 | 240V 50Hz 16A 115V 60Hz 20A |
Labstar 70 | 65 S | 310 x 310 x 680 | 700 x 617 x 820 | 4,4/ 6,0* | 400V 50Hz 16 A 220V 60Hz 25A |
Labstar 100 | 100 R | Ø 500 x 500 | 750 x 900 x 1000 | 6,0* | 400V 50Hz 16 A |
Labstar 150 | 166 R | Ø 500 x 750 | 750 x 900 x 1000 | 9,0* | 400V 50Hz 16 A |
Labstar 200 | 216 R | Ø 500 x 1000 | 750 x 900 x 1250 | 9,0* | 400V 50Hz 16 A |
R = round chamber; A = square chamber, * with steam generator
Equipment-version | Labstar 25 Labstar 40 | Labstar 70 Labstar 100 Labstar 150 Labstar 200 |
Basic Lab | Heating elements | Heating elements* |
Recommended for the sterilization of simple materials or liquids without removal dry. | ||
Dry Lab | Heating elements | Steam generator |
Recommended for the sterilization of non-infectious waste bags and materials which require intensive subsequent drying. | Membrane-vacuum pump | Water ring vacuum pump |
Quick Lab Basic | Heating elements | Heating elements* |
Recommended for the sterilization of large quantities of liquids. | Water-cooling system | Water-cooling system |
Internal heat exchanger | Internal heat exchanger | |
Air recirculation valve | ||
Quick Lab | Heating elements | Steam generator |
Recommended for the sterilization of non-infectious waste bags, large quantities of liquids and materials which require intensive subsequent drying. | Water-cooling system | Water ring vacuum pump |
Internal heat exchanger | Water-cooling system | |
Membrane-vacuum pump | Internal heat exchanger | |
Air recirculation valve | ||
Quick Lab Advanced | not available | Steam generator |
Recommended for the sterilization of non-infectious waste bags, large quantities of liquids and materials which require intensive subsequent drying – this also applies to liquids in closed containers. | Water ring vacuum pump | |
Water-cooling system | ||
Internal heat exchanger | ||
Air recirculation valve | ||
Steam/air mixture method (SAMM) | ||
Safe Lab | Heating elements | Steam generator |
Recommended for operation in the level S2 lab. Recommended for the sterilization of infectious waste bags and materials which require intensive subsequent drying. | Membrane-vacuum pump | Water ring vacuum pump |
Exhaust air filtration EAF | Exhaust air filtration EAF | |
Complete Lab | Heating elements | Steam generator |
Fully equipped laboratory autoclave for operation in the level S2 lab. Recommended for the sterilization of infectious waste bags, large quantities of liquids and materials which require intensive subsequent drying. | Membrane-vacuum pump | Water ring vacuum pump |
Exhaust air filtration EAF | Water-cooling system | |
Water-cooling system | Internal heat exchanger | |
Internal heat exchanger | Air recirculation valve | |
Exhaust air filtration EAF |
- Steam generator– integrated in the housing of the autoclave. Ensures rapid heating and cooling compared to conventional heating systems.
- Vacuum pump set– for mechanical removal of air and drying in vacuum. Possible methods include single-stage vacuum, fractionated vacuum, constant or pulsating drying under a vacuum.
- Lifting and pivoting mechanism – makes loading and unloading of vertically loaded autoclaves easier. The load capacity is 30 kg.
- Exhaust air filtration– is stipulated for the sterilization of pathogenic substances in S2/S3 laboratories, with inline condensate sterilization.
- Touch display (SteriTouch control) – enables simple and intuitive operation at the autoclave. In combination with user-friendly software, the autoclave can be operated quickly but also highly variable and simple.
- Steam-air mixture method – for the sterilization of tightly closed bottles and pressure-sensitive materials. An additional temperature sensor, air deflectors and a circulating air fan ensure precise temperature control and distribution.
- Rapid water recooling system with air-circulating fan – allows a shortening of the recooling time by more than 80% compared to the self cooling during sterilization of liquids. This is due to an internal heat exchanger, also known as a “fast cooler”, through which water flows.
Login to see price!1